CRoC® Combat Ready Clamp

$384.61

Clamping Down on Hemorrhage

Purchase of some medical devices that may be labeled “Caution” or “RX only” requires that purchaser is a licensed physician or work under the direct supervision of a licensed physician. Ensuring this supervision is the purchasers' responsibility.

*

March Medical Logo

SKU: 31-200 Categories: ,

NSN: 6515-01-589-9135

Description

The CRoC® Combat Ready Clamp is the first  COTCCC-recommended device for seven-site junctional hemorrhage control. Hemorrhage is the leading cause of preventable death on the battlefield. Approximately 25% of potentially survivable military deaths are due to uncontrolled junctional hemorrhage1— the majority of which occur in the pelvic region. When full limb amputations occur in a tactical environment, standard tourniquets cannot be used.

The CRoC®Combat Ready Clamp is the solution. Unlike inflatable, belt-like devices, the CRoC® has a vice-like compression disk that provides the distinct life saving advantage of creating bi-directional pressure exactly where it is needed most – stopping collateral flow and controlling hemorrhage. The CRoC® is lightweight, durable, collapsible, low cube and can effectively stop junctional hemorrhage in under a minute.

Product Info

Capabilities

  • TREATS seven sites in three regions (inguinal, axilla, and neck)
  • STOPS junctional hemorrhage in under a minute
  • BLOCKS collateral flow

Product Attributes

  • The first CoTCCC-recommended junctional tourniquet
  • FDA cleared for seven sites
  • Preassembled configuration deploys in 10-20 seconds
  • Rust and corrosion resistant, aircraft-grade aluminum construction
  • No add-on parts or accessories required
  • Durable, lightweight, minimal cube

Clinical Benefits

  • One device for all seven truncal junctions (inguinal, axilla, and neck)
  • Stops junctional hemorrhage in under a minute
  • Blocks collateral blood flow with bi-directional pressure
  • Hands-free once applied
  • Secure and will not slip during patient evacuation
  • Clinical effectiveness is not impacted by treatment environment (i.e. altitude or temperature)
  • Adjusts to exceed the 5th to 95th percentile population range

Specifications

  • NSN:6515-01-589-9135
  • PN: 31-200
  • FDA 510(k) Clearance
  • Single Patient Use
  • CoTCCC Recommended Product
  • Specifications:
    • Unit Dimensions
      • Packaged: 12’’L x 10’’W x 1.58’’H
    • Unit Weight: 1.45 lbs
    • Aircraft Grade Aluminum
    • Not made with natural rubber latex
  • Available Direct, Prime Vendor, ECAT, CEC and GSA
  • 100% TAA Compliant
  • Made in USA

Training

References

1 Kelly JF, Ritenour AE, McLaughlin DF, et al. Injury severity and causes of death from Operation Iraqi Freedom and Operation Enduring Freedom: 2003-2004 versus 2006.
J Trauma. 2008; 64 (2 Suppl):S21-S26; discussion S26-S27.